High-voltage electric motor 1000 kW, 1490 rpm, 6000 V, IC611, H27R 4502-4-6

Home » Shop » Electric motors » Modular high voltage electric motors H27R » Electric motor 1400 rpm high voltage » High-voltage electric motor 1000 kW, 1490 rpm, 6000 V, IC611, H27R 4502-4-6

H27R 4502-4-6 is a 1400 rpm electric motor with an output of 1000 kW and a voltage of 6000 V that, at a rated speed of 1490 rpm, corresponds to the 1400 – 1500 rpm class. IE4 Super Premium efficiency together with a welded steel frame helps limit losses and simplify handling of large assemblies. Manufacturer VYBO Electric provides reliable solutions for demanding operation. Read More

Electric motor H17R-4502-4
Power 1000 kW
Nominal voltage 6000 V (+/-10%)
Number of poles 4
Speed 1490 rpm
Frame 450 mm
Frame type welded steel

Current availability: in stock

Delivery: Free

Processo di acquisto sicuro garantito

If you need advice or help with your order, feel free to contact us.

Three-phase electric motor: H27R-4502-4 1000KW 6000V 50HZ

Basic technical data
Motor type H27R 4502-4
Rated power (kW) 1000
Frame size (mm) 450
Number of poles 4
Rated speed (rpm) 1490
Frequency (Hz) 50
Electrical parameters
Rated voltage (V) 6000
Connection Y
Rated current (A) 113,3
Efficiency at 100% load (%) 95,7
Power factor at 100% load 0,89
Starting and torque characteristics
Rated torque (Nm) 6409
Locked-rotor torque ratio (LRT/RLT) 0,70
Breakdown torque ratio (BDT/RLT) 2,0
Locked-rotor current ratio (LRA/RLA) 5,5
Rotor moment of inertia (kg·m²) 24
Load moment of inertia (kg·m²) 444
Accessories
6 x PT100 in windings
1 x PT100 in NDE bearing
1 x PT100 in DE bearing
Anti-condensation heater 230 V
3 x PTC thermistor
Applicable standards
Specification IEC60034-1
Testing IEC60034-2
Noise IEC60034-9
Vibration IEC60034-14
Construction and operating data
Mounting arrangement IM B3 (other designs on request)
Duty type S1 (S2, S3, S4 – S9 optional)
Load type Parabolic or linear curve
Degree of protection IP55
Insulation class F
Temperature rise class B
Cooling method IC611 (On request IC616, IC666)
Starting method DOL, VFD, Soft-starter
Direction of rotation Both
Vibration (mm/s) 2.8
Rotor cage copper rotor bars
Terminal box type VYBO CB1-HV
Operating conditions
Ambient temperature range (°C) -20 to +40 (-30, +50, +60 optional)
Maximum installation altitude up to 1000 m
Weight and surface finish
Approximate weight 4560 kg
Colour RAL7030
Paint finish shiny
Bearings and lubrication
DE/NDE bearings NU228-C3+6030-C3/NU228-C3
Lubricant Lithium-based grease No. 2 (temperature class)

Higher efficiency in continuous operation is essential wherever energy costs and technology availability are decisive. The H27R 4502-4-6 model with an output of 1000 kW provides stable operation for large drives, helping reduce losses in extensive operating regimes and supporting efficient production in heavy industry. This electric motor is designed as a robust three-phase electric motor for applications where long service life, reliable starting and precisely defined operating conditions are expected.

Energy savings in large drives with IE4 class

High efficiency of 95,7 % and a power factor of 0,89 mean that the motor converts supplied energy into mechanical work more effectively even during long working cycles. In practice, this brings a noticeable improvement in economy in operations where every kilowatt-hour is monitored. H27R 4502-4-6 therefore fits the high-voltage industrial drives segment where stable output without outages and an emphasis on long-term efficiency are expected from the motor.

Frame design for installation of large machines

The welded steel frame provides high rigidity while maintaining a more favourable weight characteristic than traditional massive castings. For equipment with a package weight of 4560 kg, this simplifies transport, installation and final alignment on the foundation. The frame also provides good conditions for operation in demanding environments where mechanical durability and mounting stability are monitored. This 4-pole electric motor is suitable for machines operating under high load that need a rigid base without unnecessary structural oversizing.

  • Rated current of 113,3 A supports power-supply and protection design for long-term loading.
  • A rated speed of 1490 rpm is suitable for drives requiring medium speed and high torque.
  • Rated torque of 6409 Nm provides reserve for starts and stable engagement under load.
  • Rotor inertia of 24,0 kg·m² simplifies evaluation of starting and braking dynamics.
  • Load inertia of 444,0 kg·m² is important when sizing the coupling, gearbox and starting system.

Starting and protection for heavy technologies

When designing starting, start-up parameters help when selecting contactors, a soft starter or a frequency converter within the technologically permitted operating range. Starting torque reaches 0,7 times the rated torque, breakdown torque 2 times the rated torque and starting current 5,5 times the rated current, which is important for assessing the grid, protection and torque reserve. When used in higher-voltage supply systems, including 6000 V, it is advisable to allow for precise protection settings and monitoring of thermal conditions during starting.

Temperature and bearing monitoring in continuous operation

Standard thermal protection and monitoring help maintain control over motor condition during long operating periods and load fluctuations. Insulation class F combined with temperature rise B provides a suitable basis for operation in demanding environments where reliable thermal stability is expected. The design also includes DE bearings NU228-C3+6030-C3 and NDE bearing NU228-C3, which are suitable for large industrial assemblies focused on precise mounting and long service intervals.

Typical deployment in production and power generation

H27R 4502-4-6 is used with ore crushers, pumping units for water management, large compressors, mills in cement plants, conveyors with high inertia, fans in technological blocks and mixing lines for the chemical industry. In each of these cases, stable torque, high efficiency and the mechanical durability of the frame help maintain operation at the required pace without unnecessary downtime. Monitoring of condensation and heat distribution in the winding is also appropriate, especially after long shutdowns and during restart.

If you need to verify the motor’s suitability for a specific technology, contact us.